97¹ú¼Ê

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·  £¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¬Ã¦ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
RG-IS5200-8GT4XS-DC
RG-IS5200-8GT4XS-DC
RG-IS5200-8GT4XS-DC
RG-IS5200-8GT4XS-DC
RG-IS5200-8GT4XS-DC
RG-IS5200-8GT4XS-DC
RG-IS5200-8GT4XS-DC
RG-IS5200-8GT4XS-DC
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

ɳº£ÏµÁÐ8¿ÚǧÕ×µ¼¹ìʽ¹¤Òµ¼¶ÒÔÌ«Íø½»Á÷»ú  £¬Ç§Õ×ÉÏÐÐ  £¬Ë«Â·±¸·ÝÈßÓàÊäÈë  £¬Ö§³ÖIP41  £¬RG-IS5200-8GT4XS-DC

Öª×ãÆéá«Î¡¢¿¹Õñ¶¯¡¢·ÀÀ×»÷µÈÖØ´óÇéÐÎÐèÇó  £¬ÊÊÓÃÓÚÊÒÍâ¼à¿Ø¡¢ÌØÊâÌìÆøÌõ¼þºÍÖÆÔìÒµ  £¬»¹¿É°²ÅÅÔÚɳĮ¡¢·Û³¾¿ÅÁ£´óµÄÐÂÄÜÔ´¹¤³§¡¢¼°ÑζÇÖÊ´µÄÑØº£µØÇøµÈ³¡¾°

²úÆ·ÌØÕ÷£º

  • -40¡ãC~+75¡ãC¹¤Òµ¼¶¿íÎÂ×÷Òµ  £¬Î޾屰ÁÓÇéÐÎ
  • ¹¤Òµ¼¶Ë«ÈßÓàÊäÈë  £¬Çå¾²¿É¿¿
  • ¹¤Òµ¼¶¶àÖØ·À»¤  £¬¿¹×ÌÈÅÄÜÁ¦Ç¿
  • ¹¤Òµ¼¶ÂÁºÏ½ð»úÉí  £¬ÎÞµçÉÈÉè¼Æ, ½áʵÄÍÓÃ, ¸ßЧɢÈÈ
  • Ö§³ÖVSUÐéÄ⻯  £¬ÍøÂç¹ÜÀí¸ü¼òÆÓ  £¬ÔËÐиü¸ßЧ
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

¹¤Òµ¼¶²úÆ·Éè¼Æ
ÎÞ¾åÊÒÍâ±°ÁÓÇéÐÎ  £¬×°±¸ÎȹÌÔËÐÐ

8¿ÚǧÕ×µ¼¹ìʽ¹¤Òµ¼¶ÒÔÌ«Íø½»Á÷»ú RG-IS5200-8GT4XS-DC

ÃæÏòÇå¾²¡¢¸ßЧºÍ½ÚÄܵÄÉè¼ÆÀíÄîÍÆ³öµÄÐÂÒ»´úǧÕ×ÒÔÌ«Íø½»Á÷»ú  £¬×¨Îª¹¤ÒµÇéÐÎÉè¼Æ £»DINµ¼¹ì×°Öà  £¬ÇáÓ¯ÎÞа

97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
-40°C~+75°C¹¤Òµ¼¶¿íÎÂ×÷Òµ  £¬Î޾屰ÁÓÇéÐÎ
×ñÕÕ¹¤Òµ¼¶Éè¼Æ¹æ·¶  £¬½ÓÄÉÖ÷Á÷³ÉÊ칤ҵ¼¶Ð¾Æ¬¡¢¸ßÐÔÄܹ¤Òµ¼¶CPUµÈ  £¬¿¹º®ÄÍÈÈ  £¬°ü¹ÜÔÚ-40°C~+75°C±°ÁÓÇéÐÎÏÂÎȹ̺ã¾ÃÔËÐÐ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¹¤Òµ¼¶Ë«ÈßÓàÊäÈë  £¬Çå¾²¿É¿¿
¿í·ùµçÔ´ÊäÈë, ¾ßÓзÀ·´½Ó¡¢¶Ì·¡¢¹ýÁ÷¡¢¹ýѹ± £»¤, ³¤Ð§ÊÂÇéÒ»Ö±µç
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¹¤Òµ¼¶¶àÖØ·À»¤  £¬¿¹×ÌÈÅÄÜÁ¦Ç¿
¾ßÓÐÀËÓ¿·À»¤¡¢·À³¾¡¢¿¹Õð¡¢·ÀÇÖÊ´¡¢¿¹µç´Å×ÌÈŵȶàÖØ·À»¤, °ü¹ÜÔÚÖÖÖÖ±°ÁÓÇéÐÎÏÂÎȹÌÔËÐÐ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
¹¤Òµ¼¶ÂÁºÏ½ð»úÉí  £¬ÎÞµçÉÈÉè¼Æ, ½áʵÄÍÓÃ, ¸ßЧɢÈÈ
¸ßµ¼ÈÈÂÁºÏ½ðÍâ¿ÇÍŽáÎÞµçÉÈÉè¼Æ  £¬ÎÞÔëÒôºÍ»Ò³¾ÎÛȾ  £¬±ÜÃâ¾²µç»ýÀÛºÍÇÖÊ´  £¬É¢ÈÈЧ¹û¸üÓÅÒì
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
Ö§³ÖVSUÐéÄ⻯  £¬ÍøÂç¹ÜÀí¸ü¼òÆÓ  £¬ÔËÐиü¸ßЧ
ͨ¹ýVSUÐéÄ⻯ÊÖÒÕ  £¬ÊµÏÖ¶à×°±¸Í³Ò»¹ÜÀí¡¢ºÁÃë¼¶¹ÊÕÏÇл»Óë×°±¸ÎÞаÀ©Õ¹  £¬°ü¹ÜÍøÂç¸ßЧÎȹÌÔËÐÐ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

Äú¾õÊÊÄ¿½ñÄÚÈÝÖÊÁ¿ÔõÑù£¿

²»Õ¦µÎ ºÜÊǺÃ

Äú¸ø³ö¸Ã·ÖÊýµÄÖ÷ÒªÔµ¹ÊÔ­ÓÉÊÇʲô£¿

ллÄúµÄÆÀ¼Û,ÎÒÃÇ»á½øÒ»²½Ë¢ÐÂÒÔÁè¼ÝÄúµÄÆÚÍû¡£

97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
Äú¾õÊÊÄ¿½ñÄÚÈÝÖÊÁ¿ÔõÑù£¿
²»Õ¦µÎ ºÜÊǺÃ

ллÄúµÄÆÀ¼Û,ÎÒÃÇ»á½øÒ»²½Ë¢ÐÂÒÔÁè¼ÝÄúµÄÆÚÍû¡£

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

½Ó¿Ú¹æ¸ñ

½Ó¿Ú¹æ¸ñ RG-IS5200-8GT4XS RG-IS5200-8GT4XS-DC RG-IS5200-8GT4XS-UP-DC RG-IS5200-24GT4XS-UP-DC
¹Ì»¯ÓªÒµ½Ó¿Ú 8¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú  £¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© 8¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú  £¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© 8¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú  £¬Ö§³ÖPoE/PoE+/PoE++  £¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£© 24¸ö10/100/1000BASE-T×Ô˳ӦÒÔÌ«Íø½Ó¿Ú, Ö§³ÖPoE/PoE+/PoE++  £¬4¸ö1GE/10GE SFP+½Ó¿Ú£¨ÊÚȨºóÖ§³Ö10GE£©
¹Ì»¯¹ÜÀí½Ó¿Ú 1¸öRJ45µÄConsole½Ó¿Ú
RS485½Ó¿Ú 1¸öRS485½Ó¿Ú  £¬Ö§³ÖModbusЭÒé
DIDO 1·DI  £¬1·DO
USB½Ó¿Ú 1¸öUSB 2.0¶Ë¿Ú  £¬Ö§³ÖUSBÉèÖÃÖ¸µ¼  £¬Ö§³Öͨ¹ýUÅÌÉúÑÄÈÕÖ¾¡¢µ¼³öÉèÖà  £¬Éý¼¶×°Öðü

ϵͳ¹æ¸ñ

ϵͳ¹æ¸ñ RG-IS5200-8GT4XS RG-IS5200-8GT4XS-DC RG-IS5200-8GT4XS-UP-DC RG-IS5200-24GT4XS-UP-DC
½»Á÷ÈÝÁ¿ 520Gbps/5.2Tbps
°üת·¢ÂÊ 102Mpps 183Mpps

³ß´çÓëÖØÁ¿

³ß´çÓëÖØÁ¿ RG-IS5200-8GT4XS RG-IS5200-8GT4XS-DC RG-IS5200-8GT4XS-UP-DC RG-IS5200-24GT4XS-UP-DC
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 150mm×133mm×86mm 150mm×133mm×86mm 150mm×133mm×86mm 442mm×220mm×43.6mm
²úÆ·ÖØÁ¿ 1.49kg 1.5kg 1.53kg 2.85kg
×°Ö÷½·¨ ×ÀÃæ×°Öá¢DINµ¼¹ì×°ÖᢱڹÒ×°Öà ×ÀÃæ×°Öᢻú¼Ü×°ÖᢱڹÒ×°ÖÃ

µçÔ´Ó빦ºÄ

µçÔ´Ó빦ºÄ RG-IS5200-8GT4XS RG-IS5200-8GT4XS-DC RG-IS5200-8GT4XS-UP-DC RG-IS5200-24GT4XS-UP-DC
µçÔ´½Ó¿Ú ·ï»Ë¶Ë×Ó
PoE¹©µç±ê×¼ ²»Ö§³Ö ½Ó¿Ú1~8Ö§³ÖPoE¡¢PoE+¡¢PoE++£¨IEEE802.3af/at/bt£©¹©µç ½Ó¿Ú1~24Ö§³ÖPoE¡¢PoE+¡¢PoE++£¨IEEE802.3af/at/bt£©¹©µç
PoEÊä³ö¹¦ÂÊ ²»Ö§³Ö Õû»ú×î´óPoEÊä³ö¹¦ÂÊ£º480W
PoE½Ó¿Ú×î´ó¹©µç£º15.4W(PoE)  £¬30W(PoE+)  £¬60W/90W(PoE++)
˵Ã÷£º
RG-IS5200-8GT4XS-UP-DCÉèÖÃIPA240-PµçÔ´×î´óÖ»ÄÜÌṩ210WµÄPoEÊä³ö
RG-IS5200-24GT4XS-UP-DCÉèÖÃIPA240-PµçÔ´×î´óÖ»ÄÜÌṩ200WµÄPoEÊä³ö
ÏÖʵµÄPoE´øÔØÊýÄ¿  £¬ÇëÆ¾Ö¤µçÔ´Ä£¿é¿ÉÓÃ×ܹ¦Âʼ°PoE×°±¸ÏÖʵ¹¦ÂÊÅÌËã¡£
µçÔ´ÊäÈë ½»Á÷£¨AC£©ÊäÈ룺
¶î¶¨ÊäÈëµçѹ£º100V~240V AC  £¬50/60Hz
×î´óÊäÈëµçѹ£º90V~264V AC  £¬50/60Hz
¶î¶¨ÊäÈëµçÁ÷£º0.6A
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
¶î¶¨ÊäÈëµçѹ£º240V DC
×î´óÊäÈëµçѹ£º204V~288V DC
¶î¶¨ÊäÈëµçÁ÷£º0.3A
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺
¶î¶¨ÊäÈëµçѹ£º12V~48V DC
×î´óÊäÈëµçѹ£º9.6V~60V DC
¶î¶¨ÊäÈëµçÁ÷£º2A~0.5A
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺
¶î¶¨ÊäÈëµçѹ£º56V DC
×î´óÊäÈëµçѹ£º54~57V DC£¨Ö§³ÖPoE/PoE+/PoE++£©»ò48V DC£¨½öÖ§³Ö PoE£©
¶î¶¨ÊäÈëµçÁ÷£º10A
˫·±¸·ÝÈßÓàÖ±Á÷£¨DC1/DC2£©ÊäÈ룺
¶î¶¨ÊäÈëµçѹ£º12VDC¡¢56V DC
²»Ö§³ÖPoE£º12V DC
½öÖ§³ÖPoE¹©µç£º48V DC
Ö§³ÖPoE/PoE+/PoE++¹©µç£º54~57V DC
×î´óÊäÈëµçѹ£º9.6~60V DC
¶î¶¨ÊäÈëµçÁ÷£º10A£¨56Vdc£©¡¢4A£¨12Vdc£©
Õû»ú×î´ó¹¦ºÄ 16.8W 19.8W 23.8W (ÎÞPoE¸ºÔØ)
503.8W (PoEÂúÔØ)
12VÖ±Á÷µçÔ´ÊäÈ룺
36.8W
56VÖ±Á÷µçÔ´ÊäÈ룺
35.5W (ÎÞPoE¸ºÔØ)
515.5W (PoEÂúÔØ)

ÇéÐÎÓë¿É¿¿ÐÔ

ÇéÐÎÓë¿É¿¿ÐÔ RG-IS5200-8GT4XS RG-IS5200-8GT4XS-DC RG-IS5200-8GT4XS-UP-DC RG-IS5200-24GT4XS-UP-DC
·À³¾·ÀˮƷ¼¶ IP41  £¬Í¨¹ýÑ¡ÅäIS52-shield¿ÉÖ§³ÖIP55·À»¤Æ·¼¶
˵Ã÷£ºÂã»úÏÂIP41·À»¤ÄÜÁ¦ÒªÇóÇ°Ãæ°å¶Ë¿Ú²»ÏòÉÏ×°ÖÃ
IP40
·ÀÀ× ACµçÔ´½Ó¿Ú£º¹²Ä£6kV/²îÄ£6kV£¨BÅоݣ©
ÓªÒµ½Ó¿Ú£º¹²Ä£10kV/²îÄ£500V(RÅоÝ)
ÊÂÇéÎÂ¶È ÊÂÇéÇéÐÎζȣº(0m¡«1800m º£°Î  £¬ÅäÌ×¹¤Òµ¼¶¹âÄ£¿é)
–40°C¡«+65°C£¨×°ÖÃÔÚÃÜ·â¹ñ£©
–40°C¡«+70°C£¨×°ÖÃÔÚ͸·ç¹ñ  £¬Í¸·ç·çËÙÖÁÉÙΪ 80LFM £¨Line Feet Minute£©)
–40°C¡«+75°C£¨×°ÖÃÔÚ×Ô´øµçÉȵÄ͸·ç¹ñ  £¬Í¸·ç·çËÙÖÁÉÙΪ 200LFM£©
˵Ã÷£ºÔÚº£°Î1800m~5000m¹æÄ£ÄÚ, º£°ÎÿÉý¸ß220m  £¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£
´æ´¢ÇéÐÎζȣº–40¡æ~+85¡æ
ÊÂÇéÇéÐÎζȣº(0m¡«1800m º£°Î  £¬ÅäÌ×¹¤Òµ¼¶¹âÄ£¿é)
–40°C¡«+60°C£¨×°ÖÃÔÚÃÜ·â¹ñ  £¬RG-IS5200-8GT4XS-UP-DCÊä³öPoE¹¦ÂÊ480W£©
–40°C¡«+65°C£¨×°ÖÃÔÚÃÜ·â¹ñ  £¬ RG-IS5200-8GT4XS-UP-DCÊä³öPoE¹¦ÂÊ210W  £¬RG-IS5200-24GT4XS-UP-DC£©
–40°C¡«+70°C£¨×°ÖÃÔÚ͸·ç¹ñ  £¬Í¸·ç·çËÙÖÁÉÙΪ 80LFM £¨Line Feet Minute£©)
–40°C¡«+75°C£¨×°ÖÃÔÚ×Ô´øµçÉȵÄ͸·ç¹ñ  £¬Í¸·ç·çËÙÖÁÉÙΪ 200LFM£©
˵Ã÷£ºÔÚº£°Î1800m~5000m¹æÄ£ÄÚ, º£°ÎÿÉý¸ß220m  £¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£
´æ´¢ÇéÐÎζȣº–40¡æ~+85¡æ
ʪ¶È ÊÂÇéÇéÐÎʪ¶È£º10%RH~90%RH
´æ´¢ÇéÐÎʪ¶È£º5%RH~95%RH
º£°Î ÊÂÇ麣°Î£º0~5000m
´æ´¢º£°Î£º0~5000m
ƽ¾ùÎÞ¹ÊÕÏʱ¼ä£¨MTBF£© 40¡æÒÔÏ´óÓÚ300000Сʱ£¨Ô¼34Ä꣩
µçÉÈ ÎÞµçÉÈ  £¬×ÔȻɢÈÈ
µçÔ´¼à¿Ø ²»Ö§³Ö µçÔ´ÔÚλ¼ì²â£ºÖ§³Ö
ÎÂ¶È¼à¿Ø Ö§³ÖÎÂ¶È¼à¿Ø¡¢Î¶ȸ澯¡¢¹ýα £»¤
¾²µç¿¹ÈÅ ±ê×¼²âÊÔ½Ó´¥/¿ÕÆø£º6kV/8kV
ÄÍÊÜÐÔ½Ó´¥/¿ÕÆø£º8K/15K
¹¤Æµ´Å³¡ ÎȹÌÒ»Á¬´Å³¡£º30A/m
¶Ìʱ×÷Óôų¡£º300A/m
´«µ¼¿¹ÈÅ ÐÔÄÜÅоݣºA
ɨƵ¹æÄ££º0.15¡«80MHz
µ÷ÖÆ£º80%AM¡¢1kHzÕýÏÒ²¨
ACµçÔ´½Ó¿Ú£º3V
ÓªÒµ½Ó¿Ú£º3V
DI½Ó¿Ú/DO½Ó¿Ú/RS485½Ó¿Ú £º3V
ÐÔÄÜÅоݣºA
ɨƵ¹æÄ££º0.15¡«80MHz
µ÷ÖÆ£º80%AM¡¢1kHzÕýÏÒ²¨
ÊÊÅäÆ÷ACµçÔ´½Ó¿Ú£º3V
ÓªÒµ½Ó¿Ú£º3V
DI½Ó¿Ú/DO½Ó¿Ú/RS485½Ó¿Ú £º3V
µçѹµøÂä ACµçÔ´¿Ú£º
¡ñ Ê£Óàµçѹ70£¥  £¬¼á³Ö25ÖÜÆÚ£¨ÅоÝB£©
¡ñ Ê£Óàµçѹ0£¥  £¬¼á³Ö0.5ÖÜÆÚ£¨ÅоÝB£©
¡ñ Ê£Óàµçѹ0£¥  £¬¼á³Ö1ÖÜÆÚ£¨ÅоÝB£©
¡ñ Ê£Óàµçѹ0£¥  £¬¼á³Ö250ÖÜÆÚ£¨ÅоÝC£©
ÊÊÅäÆ÷ACµçÔ´½Ó¿Ú£º
¡ñ Ê£Óàµçѹ70£¥  £¬¼á³Ö25ÖÜÆÚ£¨ÅоÝB£©
¡ñ Ê£Óàµçѹ0£¥  £¬¼á³Ö0.5ÖÜÆÚ£¨ÅоÝB£©
¡ñ Ê£Óàµçѹ0£¥  £¬¼á³Ö1ÖÜÆÚ£¨ÅоÝB£©
¡ñ Ê£Óàµçѹ0£¥  £¬¼á³Ö250ÖÜÆÚ£¨ÅоÝC£©
г²¨ ƾ֤IEC61000-3-2  £¬GB17625.1  £¬Öª×ãAÀà×°±¸ÏÞÖµ

ÈÏÖ¤Óë¹æÔò

ÈÏÖ¤Óë¹æÔò RG-IS5200-8GT4XS RG-IS5200-8GT4XS-DC RG-IS5200-8GT4XS-UP-DC RG-IS5200-24GT4XS-UP-DC
EMC¹æÔò GB 9254-2008, CLASS A

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ
MACµØÖ·±í Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖIP subnet-based VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
¶þ²ã»·ÍøÊÖÒÕ Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS  £¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·¼æÈÝ
Ö§³ÖSTP
Ö§³ÖRSTP
Ö§³ÖMSTP
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨
Ö§³ÖLACP¾²Ì¬¡¢¶¯Ì¬¾ÛºÏ
Ö§³Ö¿çVSU AP
Mirror Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢·´Éä¿ÚÒ»¶Ô¶àµÄ¾µÏñ  £¬Ö§³ÖRSPAN
Ö§³Ö¿ç×°±¸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
VSUÌØÕ÷ Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ
Ö§³ÖÍâµØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Öͨ¹ý±ê×¼ÓªÒµ¿ÚʵÏÖÐéÄ⻯
ÁãÉèÖà ֧³ÖCWMP(TR069)ЭÒé±ê׼ЭÒé
IP·ÓÉ IPv4/IPv6 ¾²Ì¬Â·ÓÉ
RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3
Routing Policy
ACL Ö§³Ö±ê×¼IP ACL
Ö§³ÖÀ©Õ¹IP ACL
Ö§³ÖMACÀ©Õ¹ACL
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³Öר¼Ò¼¶ACL
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
IPv6»ù´¡Ð­Òé IPv6±àÖ·¡¢ÁÚÈË·¢Ã÷ЭÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/ IP precedenceÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢SP+WRR¡¢SP+DRRÐÐÁе÷Àí
Çå¾²ÌØÕ÷ Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤
Ö§³ÖARP Check
Ö§³ÖDAI
Ö§³Ö·ÀÍø¹ØARPÓÕÆ­
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî± £»¤
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖBPDU Guard
Ö§³ÖIP Source Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú± £»¤
¹ÜÀíÌØÕ÷ SNMP¡¢CLI(Telnet/Console)¡¢RMON(1  £¬2  £¬3  £¬9)¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢sFLOW

Õö¿ªÏêϸ²ÎÊý

Ó¦ÓôîÅä

ÖÆÔìÆóÒµ³¡¾°
ÊÒÍâ¼à¿Ø³¡¾°

ÍòÕ×¹âÏËÏß

10G

ǧÕ×¹âÏËÏß

1000M

ǧÕ×Ë«½ÊÏß

1000M
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

³£¼ûÎÊÌâ

ÔÝÎÞÎÊÌâ  £¬ÎÒÒªÌáÎÊ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿
Á¬Ã¦×Éѯ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµAIÖúÊÖ
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£©£¿
Äú¶ÔÎĵµÊÇ·ñÉÐÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
Ϊ¾¡¿ì½â¾öÎÊÌâ  £¬ÇëÄúÁôÏÂÁªÏµ·½·¨Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
97¹ú¼Ê¡¤(ÖйúÇø)¼¯ÍŹٷ½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼